Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Biomed Opt ; 27(6)2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35676754

RESUMO

SIGNIFICANCE: Growing levels of obesity and metabolic syndrome have driven demand for more advanced forms of body composition assessment. While various techniques exist to measure body composition, devices are typically expensive and not portable, involve radiation [in the case of dual-energy x-ray absorptiometry (DXA)], and are limited to analysis of adiposity while metabolic information from blood supply and oxygenation are not considered. AIM: We evaluate whether diffuse optical spectroscopic imaging (DOSI) can be used to predict site-specific adiposity and percent fat (whole body) while simultaneously providing information about local tissue hemoglobin levels and oxygenation. APPROACH: DOSI measures of tissue composition in gastrocnemius, quadriceps, abdomen, and biceps, DXA whole-body composition, and ultrasound-derived skin and adipose tissue thickness (SATT) in the quadriceps were obtained from 99 individuals aged 7 to 34 years old. RESULTS: Various DOSI-derived parameters were correlated with SATT and an optical method is proposed for estimating SATT using a newly defined parameter, the optical fat fraction (OFF), which considers all parameters that correlate with SATT. Broadband absorption and scattering spectra from study participants with the thinnest (SATT ≈ 0.25 ± 0.02 cm) and thickest SATT (SATT ≈ 1.55 ± 0.14 cm), representing best estimates for pure in vivo lean and fatty tissue, respectively, are reported. Finally, a trained prediction model is developed which allows DOSI assessment of OFF to predict DXA body-fat percentage, demonstrating that DOSI can be used to quantify body composition. CONCLUSIONS: This study shows that DOSI can be used to assess the adiposity of specific tissues or the entire human body, and the OFF parameter is defined for corroboration and further evaluation in future research.


Assuntos
Tecido Adiposo , Composição Corporal , Tecido Adiposo/diagnóstico por imagem , Adolescente , Adulto , Criança , Humanos , Músculo Esquelético/diagnóstico por imagem , Obesidade , Análise Espectral , Adulto Jovem
2.
Br J Haematol ; 196(1): 179-182, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34312843

RESUMO

We used near-infrared spectroscopy to examine tissue oxygenation (StO2) during exercise in 17 children and young adults with sickle cell anaemia (SCA) and 13 controls. Patients had lower cerebral StO2 at all exercise stages and demonstrated significantly greater decreases in cerebral StO2 later during exercise. Quadriceps StO2 increased similarly in patients and controls during early exercise, but decreases from baseline were greater in patients during later exercise. At similar workloads, patients demonstrated lower cerebral StO2 (69·2 ± 6·6 vs. 79·5 ± 5·3%, P < 0·001) and trended towards lower quadriceps StO2 (67·7 ± 9·0 vs. 73·2 ± 7·9%, P = 0·09) . Further studies of tissue oxygenation during exercise in SCA are warranted.


Assuntos
Anemia Falciforme/metabolismo , Córtex Cerebral/metabolismo , Exercício Físico , Músculo Esquelético/metabolismo , Oxigênio/metabolismo , Adolescente , Fatores Etários , Anemia Falciforme/diagnóstico , Anemia Falciforme/genética , Anemia Falciforme/terapia , Biomarcadores , Criança , Pré-Escolar , Feminino , Humanos , Masculino , Adulto Jovem
3.
J Hazard Mater ; 371: 62-71, 2019 06 05.
Artigo em Inglês | MEDLINE | ID: mdl-30844651

RESUMO

This article presents a laboratory study investigating the effects of RHA on the immobilisation of lead and copper in a slurry treated with a binder content ranging from 100 to 300 kg/m3. Increased binder content was significant in the immobilisation of Pb, but less effective for Cu. A minimum binder content of 200 kg/m3 was required to stabilise Cu in the slurry. The incorporation of RHA significantly reduced the coefficient of diffusion of Pb and Cu spiked samples in comparison to samples treated with only cement. Sorption and precipitation reaction were important mechanisms that controlled the leaching of Cu and Pb. The increase of RHA content led to increase in sorption and precipitation reaction in the solidified/stabilised matrix. The results from mercury intrusion porosimetry (MIP) revealed that specimen spiked with Cu exhibited more macropores than those spiked with Pb. It is postulated that the cement hydration may be retarded due to the presence of Cu. The performance of the RHA stabilised samples is influenced significantly by the pH. The amount of binder content was crucial for Cu and Pb leachability. The presence of RHA offered little resistance under acidic conditions but minimised the leachability under neutral and alkaline conditions.


Assuntos
Materiais de Construção/análise , Cobre/análise , Chumbo/análise , Oryza/química , Difusão , Cinética
4.
Sci Total Environ ; 612: 1123-1131, 2018 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-28892856

RESUMO

Groundwater pollution by leachate leakage is one of the most common environmental hazards associated with municipal solid waste (MSW) landfill sites. However, landfill leachate contains a large variety of pollutants with widely different concentrations and biotoxicity. Thus, selecting leachate pollutant indicators and levels for identifying breakthrough of barrier systems are key factors in assessing their breakthrough times. This study investigated the transport behavior of leachate pollutants through landfill barrier systems using centrifuge tests and numerical modeling. The overall objective of this study is to investigate breakthrough mechanism to facilitate the establishment of a consistent pollutant threshold concentration for use as a groundwater pollution alert. The specific objective of the study is to identify which pollutant and breakthrough threshold concentration should be used as an indicator in the transport of multiple pollutants through a landfill barrier system. The threshold concentration from the Chinese groundwater quality standards was used in the analysis of the properties of leachates from many landfill sites in China. The time for the chemical oxygen demand (COD) to reach the breakthrough threshold concentration at the bottom of a 2m compacted clay liner was 1.51years according to centrifuge tests, and 1.81years according to numerical modeling. The COD breakthrough times for single and double composite liners were within the range of 16 and 36.58years. Of all the pollutants, COD was found to consistently reach the breakthrough threshold first. Therefore, COD can be selected as the key indicator for pollution alerts and used to assess the environmental risk posed by MSW landfill sites.

5.
J Cereb Blood Flow Metab ; 37(3): 1030-1045, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27174996

RESUMO

Stroke is the leading cause of adult disability. Systemic delivery of candidate neural repair therapies is limited by the blood-brain barrier and off-target effects. We tested a bioengineering approach for local depot release of BDNF from the infarct cavity for neural repair in chronic periods after stroke. The brain release levels of a hyaluronic acid hydrogel + BDNF were tested in several stroke models in mouse (strains C57Bl/6, DBA) and non-human primate ( Macaca fascicularis) and tracked with MRI. The behavioral recovery effects of hydrogel + BDNF and the effects on tissue repair outcomes were determined. Hydrogel-delivered BDNF diffuses from the stroke cavity into peri-infarct tissue over 3 weeks in two mouse stroke models, compared with 1 week for direct BDNF injection. Hydrogel delivery of BDNF promotes recovery of motor function. Mapping of motor system connections indicates that hydrogel-BDNF induces axonal sprouting within existing cortical and cortico-striatal systems. Pharmacogenetic studies show that hydrogel-BDNF induces the initial migration of immature neurons into the peri-infarct cortex and their long-term survival. In chronic stroke in the non-human primate, hydrogel-released BDNF can be detected up to 2 cm from the infarct, a distance relevant to human functional recovery in stroke. The hydrogel can be tracked by MRI in mouse and primate.


Assuntos
Fator Neurotrófico Derivado do Encéfalo/farmacologia , Hidrogel de Polietilenoglicol-Dimetacrilato/uso terapêutico , Neurogênese/efeitos dos fármacos , Recuperação de Função Fisiológica/efeitos dos fármacos , Acidente Vascular Cerebral/tratamento farmacológico , Animais , Fator Neurotrófico Derivado do Encéfalo/administração & dosagem , Sistemas de Liberação de Medicamentos/métodos , Macaca fascicularis , Imageamento por Ressonância Magnética , Camundongos , Acidente Vascular Cerebral/fisiopatologia
6.
Microcirculation ; 23(4): 293-300, 2016 05.
Artigo em Inglês | MEDLINE | ID: mdl-26998587

RESUMO

OBJECTIVES: To determine whether stability/accuracy of post-occlusive LDF following shortened, one-minute blood flow occlusion, increases in the post-exercise state or by averaging multiple measurements. METHODS: Six healthy adults (3F) underwent LDF eight times at rest and following exercise, assessing post-occlusive (one-minute occlusion) reactive hyperemia in the cutaneous microcirculation of the forefinger. Measured variables included: pre- and post-occlusion steady-state perfusion (Plat1, Plat2), maximum post-occlusive perfusion (Max), PkT, and the ratio Max/Plat1. RESULTS: Stability/accuracy of all variables improved performing measurements after exercise (p < 0.05 Plat 1, Plat 2, Max and Max/Plat1). PkT and Max/Plat 1 displayed the greatest accuracy at rest (26.6 ± 5.1% and 26.6 ± 4.4% average difference, %Diff, of single measurements from individual "true" means, respectively); for these variables, %Diff improved to 19.5 ± 5.3 and 17.6 ± 2.1, respectively, following exercise. Overall, averaging multiple measurements performed at rest also improved stability/accuracy in all variables. This improvement was comparable to that obtained with a single measurement following exercise. CONCLUSIONS: A standardized exercise stimulus prior to testing significantly improves stability/accuracy of LDF following shortened, one-minute blood flow occlusion. Our results suggest the possibilities of broader applications of exercise to optimize measurements from a variety of skin perfusion methodologies.


Assuntos
Exercício Físico/fisiologia , Fluxometria por Laser-Doppler/normas , Microcirculação/fisiologia , Adulto , Feminino , Dedos/irrigação sanguínea , Humanos , Hiperemia/fisiopatologia , Fluxometria por Laser-Doppler/métodos , Masculino , Fluxo Sanguíneo Regional , Reprodutibilidade dos Testes , Pele/irrigação sanguínea , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...